Paper 5: Volume 5 No.2 Sept 2006 Edition
Comparative
Energy Analysis of a Constant Air Volume (CAV) System and a Variable Air
Volume (VAV) System for a Software Laboratory
Kalaiselvam.
S1, Vidhya sagar Velichet.1, Iniyan. S1
and Anand A. Samuel2
1Refrigeration
and Air Conditioning Division, Department of Mechanical Engineering,
Anna
University
,
Chennai
,
India
.
2President, ISHRAE Chennai chapter,
Vellore Institute of
Technology, Deemed University,
Vellore
,
India
Buy
paper for email delivery
Credit Card or PayPal
Abstract
The objective of heating,
ventilating and air conditioning (HVAC) systems is to satisfy users when
it comes to health, indoor air quality (IAQ), and thermal comfort. Air
conditioning systems employed to provide thermal comfort and indoor air
quality consume a significant part of building energy requirements. Any
effort to minimise energy consumption improves cost effectiveness and
economics. A variable air volume (VAV) system is a choice in that
direction. In this research, a relative energy consumption analysis of a
constant air volume (CAV) system and VAV system has been performed. For
the purpose of this study, a software laboratory was taken and the load
pattern was determined. For the derived load pattern an energy analysis of
major components of the HVAC system was carried out. It was found that
energy savings in the chiller varied from 14 % to 20 % and that
fan energy savings were between 20 % and 48 %. To meet indoor
air quality (IAQ) requirements a ventilation strategy based on air quality
demand control ventilation (DCV) was evaluated. This took into account the
contaminants generated from both human and other sources such as the
building and equipment, etc.
Key words: variable air
volume (VAV), demand control ventilation (DCV), energy savings, indoor air
quality, thermal comfort, HVAC component energy analysis, variable
occupancy.
References
Ameen A and Mahmud K:
(2005) “Energy performances of prototype VAV and CAV systems under
simulated humid tropical climates”, ASHRAE Transactions,
pp320-327.
ASHRAE: (1999) ANSI/ASHRAE
Standard 62-1999 “Ventilation for Acceptable Indoor Air Quality”,
American Society of Heating Refrigerating and Air Conditioning Engineers,
Atlanta
,
GA.
EPA: (1991) “Office of
Air and Radiation Indoor Air Facts No. 4:
Sick
Building
Syndrome”. Environmental
Protection Agency
,
U.S.
Engdahl F and Johansson D:
(2004) “Optimal supply air temperature use with respect to energy use in
a variable air volume system”, Energy and Buildings, (36), pp
205-218.
Sauer HJ and Howell RH:
(1992) “Estimating the indoor air quality and energy performance of VAV
systems”, ASHRAE Journal, pp 43-50.
Moncef K and Alawi MAL:
(2004) “Analysis of the impact of CO2 based Demand-
Controlled Ventilation Strategies on Energy Consumption”, ASHRAE
Transactions, pp 274-286.
Mumma SA and Bolin RJ:
(1997) “Energy optimized ventilation constrained variable air volume
system control”, Automation in Construction, (6), pp 463-471.
Mumma SA and Yu-Pei Ke:
(1997) “Using carbon dioxide measurements to determine occupancy for
ventilation controls”, ASHRAE Transactions, pp 365-374.
Reddy TA, Liu M and
Claridge
DE
: (1998) “A study of energy use and satisfactory zone ventilation of
different outdoor air ventilation strategies terminal reheat variable air
volume systems”, Energy and Buildings, (29), pp 65-75.
Sekhar
SC
: (1997) “A critical evaluation of variable air volume system in hot and
humid climates”, Energy and Buildings, (26) pp223-232.
Wang S and Xu X: (2004)
“Optimal and robust control of outdoor ventilation air flow rate for
improving energy efficiency and IAQ”, Building and Environment,
(39), pp763-773.
Inoue U and Matsuomoto T:
(1979) “A study on energy savings with variable air volume systems by
simulation and field measurement”, Energy and Buildings, pp27-36.
Yiquan P, Zhou H, Huang Z,
Zeng Y and Long W: (2003) “Measurement and simulation of indoor air
quality and energy consumption in two Shangai office buildings with
variable air volume systems”, Energy and Buildings, (35)
pp877-891.
|