The International                        UPDATED 22nd May 2011
Journal of Ventilation
Published Quarterly www.ijovent.org.uk          Subscribe to Journal  Online 

June 2011 Edition of the IJV now Published  Call for Papers

Guide to Energy
Efficient Ventilation
(
click here for details)

£29 (GBP) Including
Postage

IJV now included in the Science Citation Index

 

 

Home
Contacting the IJV
Privacy Statement
Subscription Details
Editorial Board
IJV Online
IJV Shop
IJV Vol 1 Contents
IJV Vol 2 Contents
IJV Vol 3 Contents
IJV Vol 4 Contents
IJV Vol 5 Contents
IJV Vol 6 Contents
IJV Vol 7 Contents
IJV Vol 8 Contents
IJV Vol 9 Contents
IJV Vol 10 Contents
Journal of Ventilation
Guide to Ventilation
The Editor
Copyright
Disclaimer

 

The International  Journal of Ventilation
Volume 3 No 2 September 2004:

Paper 5: Controllable Background Ventilation in Dwellings - The Equivalent Opening Area Needed to Achieve Appropriate Indoor Air Quality 

I Ridley, J Fox, and T Oreszczyn

Bartlett School of Graduate Studies, University College London, Torrington Place Site,
Gower Street, London, WC1E 6BT  

Abstract

In dwellings there is a desire to reduce ventilation heat loss, by reducing uncontrollable air infiltration, at the same time as providing adequate indoor air quality by controllable background ventilation.  In England and Wales, the background ventilation requirements in part F of the Building Regulations at present are expressed in prescriptive terms. The adopted European Standard, EN13141-1:2004, provides a means of assessing the performance of background ventilation devices, such as trickle ventilators, and gives a standard method of measuring the equivalent area of the ventilator.  This paper compares the levels of background ventilation produced by background ventilators with the presently required free area of 4000 mm2, to that produced by larger vents, with an equivalent area of 4000 mm2. Two computer models of a domestic dwelling are used to predict the ventilation rates and relative humidities achieved in houses with different levels of background air tightness, when fitted with trickle ventilators of different equivalent areas. The simulations suggest that both background ventilators that have a free area of 4000mm2 and background ventilators with an equivalent area of 4000 mm2, provide an adequate ventilation rate, (that is average heating season ventilation rate of approximately 0.5 ach-1), and adequate IAQ, (including average heating season RH<70%), when fitted in a semi detached dwelling that achieves currently recommended levels of air tightness of 10 m3/hr.m2 at 50 Pa, and in tight dwellings with levels of air tightness of 5 m3/hr.m2 at 50 Pa.

Key words:  background ventilation, air infiltration, dwellings, indoor air quality, computer simulation.

 
 